Failures during vRA patch installation


Failures during vRA patch installation

Rated NaN out of 5 stars.

Was working on a brand new installation of vRA 7.4 where we were attempting to patch with the latest one under KB 56618

While implementing , it was throwing a straight exception right after the upload’s completed

Below was the exception in /var/log/vmware/vcac/vcac-config.log

But actual exception on why the failure was under IAAS node’s Management Agent All.log

Failure was seen because IAAS was unable to fetch binaries from vRA Appliance

On vRA Virtual Appliance nodes, open /etc/hosts file, find the entry for IPv4 loopback IP Address (127.0.0.1). Make sure that the ‘Fully Qualified Domain Name’ of the node immediately follows ‘127.0.0.1’, before ‘localhost’.

** Example: 127.0.0.1 FQDN_HOSTNAME_OF_NODE localhost

In our case it was as below

/etc/hosts was

VAMI_EDIT_BEGIN

Generated by Studio VAMI service. Do not modify manually.

127.0.0.1 localhost

10.36.19.50 vraapp01.pslab.org vraapp01

127.0.0.1 vraapp01.pslab.org load-balancer-host

VAMI_EDIT_END

Actually it should be

VAMI_EDIT_BEGIN

Generated by Studio VAMI service. Do not modify manually.

127.0.0.1 vraapp01.pslab.org vraapp01 localhost

::1 vraapp01.pslab.org vraapp01 localhost ipv6-localhost ipv6-loopback

VAMI_EDIT_END

127.0.0.1 localhost.localdom

127.0.0.1 vrava-lb.pslab.org load-balancer-host

This change has been documented in the Patch KB as well.

Here are the screenshots for failure and successful patch installation

#vRealizeAutomation